AURORA-10S 10.4 inch isingaremi isina waya yemurwere yekutarisa ine printer Masimo Spo2 sarudzo
AURORA-10S 10.4-inch isina huremu isina waya inotarisisa ine anodhinda Masimo SpO2sarudzo
Patient monitor
Product Detail:
◆Chiratidzo chekugadzirisa zvisiri izvo uye kuongorora kusashanda
◆Patient info input management function
◆Multi-lead ECG waveforms inoratidzira muchikamu
◆ Hombe yakakura yetabular uye graphic maitiro ekuchengetedza ruzivo uye nyore kuyeuka
◆ Bata dynamic waveforms
◆ Kusvikira kumaawa mashanu ekushanda simba rekuvaka-in rechargeable lithium battery
◆Unique accessory management cabinet
◆ Networking capacity
◆Sarudzo: EtCO2, 5AH Lithium bhatiri, wireless communication module (WIFI, GPRS), touch screen, IBP, AG.
Accessories
Optional modular
Technique parameters
Standard configuration | |
Sikirini | |
Display Type | 10 ″ ruvara TFT LCD |
Resolution | 800 × 600 pixels |
Waveforms | Kusvika ku7 |
ECG | |
Input | 3/5 waya ECG tambo |
Kutungamira chikamu | I II III aVR, aVL, aVF, V |
Wana sarudzo | *0.25, *0.5, *1, *1.2 |
Kutsvaira nekukurumidza | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
Chiyero chemoyo | 15-30bpm |
Calibration | ±1mv |
Kururama | ±1bpm kana ±1% (sarudza iyo data hombe) |
NIBP | |
Test method | Oscillometer |
Uzivi | Vakuru, Vana uye Neonate |
Chiyero mhando | Systolic Diastolic Mean |
Measurement parameter | Otomatiki, Kunoenderera kuyerwa |
Measurement method Manual | mmHg kana ±2% |
SPO2 | |
Display Type | Waveform, Data |
Chiyero chiyero | 0-100% |
Kururama | ± 3% (pakati pe70% -100%) |
Pulse rate range | 20-300bpm |
Kururama | ±1bpm kana ±2% (sarudza iyo data hombe) |
Resolution | 1bpm |
2-Tembiricha (Rectal & Surface) | |
Nhamba yematanho | 2 channels |
Chiyero chiyero | 0-50 ℃ |
Kururama | ±0.2℃ |
Display | T1, T2, ☒T |
Unit | ºC/ºF sarudzo |
Refresh cycle | 1s-2s |
Kufema (Impedance & Nasal Tube) | |
Chiyero mhando | 0-150 rpm |
Kururama | ± 1bm kana ± 5%, sarudza data hombe |
Resolution | 1rpm |
Optional configuration | |
EtCO2-Plug & Tamba | |
Chiyero mhando | Side stream |
Chiyero chiyero | 0-10.0%;0-76mmHg |
Kururama | <5.0%, ±0.28kPa;±2mmHg |
>5.0%, ±10% | |
2-IBP (kusarudza) | |
Chiyero chiyero | 10–300mmHg |
Nhamba yematanho | 1 kana 2 chiteshi |
Kururama | ± 1mmHg kana ± 2%, sarudza data hombe |
Pressure tag | ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP |
12 inotungamira ECG (optional) | |
Input | 3/5/10 waya ECG tambo |
Kutungamira chikamu | I, II, III aVR, aVL, aVF, V(V1-V6) |
Chiyero chemoyo | 15-380bpm |
Calibration | ±1mv |